Description
Plena Two-zone Call Station PLE‑2CS
- Modern two-zone call station for the PLE series
- Selectable gain
- Speech filter and limiter
- Output level control
- Loop-through option for up to 8 call stations
The Bosch Plena Two-zone Call Station PLE‑2CS is a modern, highquality call station with a stable metal base design, a flexible microphone stem and a unidirectional condenser microphone. It can make calls to selected zones in a public address system built with the PLE series two-zone mixer and mixer amplifiers. In addition to tabletop use, the Plena design allows neat flushmounting in desktops.
Functions
Gain, speech filter and intelligibility
This call station features selectable gain, a selectable speech filter, and a limiter for improved intelligibility.
Range
The call station has a balanced line level output, giving it a maximum range of 200 meters from the mixer, when using CAT-5 extension cables.
Loop-through
With the loop-through RJ-45 connector, it is possible to daisy chain multiple call stations.
Priority
The priority is automatic i.e. the call station nearest the mixer has priority and can override a call station further from the mixer. When a call is being made by a higher priority call station, a yellow light will display on the lower priority call stations.
Dip switches and status
DIP switches at the base of the call station select different microphone gain levels, chimes, and the speech filter. A service accessible rotary control provides microphone level attenuation. LEDs on the call station show which zones have been selected. An additional LED give visible feedback on the active state of the microphone and the system:
• Green flashing means standby (chime is sounding)
• Green indicates microphone active
• Amber indicates a higher priority call
Controls and indicators
• 2 x status LEDs
• PTT key
• 2 x zone selection keys
• 2 x zone selection LEDs
• DIP switches
• Rotary volume control
Interconnections
• 2 x RJ45 jacks
Parts included
Quantity Component
1 PLE-2CS Plena two-zone call station
1 Cable terminated with a lockable CAT-5 connector
Technical specifications
Electrical
Voltage range 24 VDC supplied by PLE mixer amplifier or mixer
Current consumption <30 mA
Performance
Nominal sensitivity 85 dB SPL (gain preset 0 dB)
Nominal output level 700 mV
Input sound level (max) 110 dB SPL
Gain preset -15 / 0 / +6 dB
Limiter threshold 2 V
Compression ratio limiter 1:20
Distortion <0.6% (maximum input)
Input noise level (equiv.) 25 dB SPLA
Frequency response 100 Hz to 16 kHz
Speech filter -3 dB at 315 Hz, high-pass, 6 dB/oct
Output impedance 200 ohm
Selections
Chimes 6
Mechanical
Base dimensions (H x W x D)without microphone 40 x 100 x 235 mm (1.57 x 3.97 x9.25 in)
Stem length with microphone 390 mm (15.35 in)
Cable length 5 m (16.4 ft)
Weight Approx. 1 kg (2.2 lb)
Mounting Standalone
Color Charcoal with silver
Environmental
Operating temperature -10 ºC to +45 ºC (14 ºF to +113 ºF)
Storage and transport temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF)
Relative humidity <95%
Ordering information
PLE‑2CS Plena Two-zone Call Station
Two zone call station with metal-base design, flexible microphone stem with unidirectional condenser microphone, two-zone selection. Order number PLE-2CS
Reviews